EIGA to amend 5.2.1.9.2(a) to ensure that orientation arrows were placed on closed cryogenic receptacles see annex 2.
The Ad Hoc Working Group noted that the UN Model Regulations did not require periodic inspections for closed cryogenic receptacles.
pressure drums, closed cryogenic receptacles and bundles of cylinders;
pressure drums, closed cryogenic receptacles and bundles of cylinders;
Each connection on a closed cryogenic receptacle shall be clearly marked to indicate its function e.g. vapour
New UN text, except that this requirement appears in ADR for closed cryogenic receptacles.
Insert NOTE 2 as follows:"NOTE 2: For closed cryogenic receptacle, see NOTE to 6.2.1.3.3.5.
For closed cryogenic receptacles the test pressure equals 1.3 times the maximum allowable working pressure,
Closed cryogenic receptacles shall be subjected to periodic inspections
By derogation from 6.2.1.6.1(d) closed cryogenic pressure receptacles shall be inspected to verify external conditions,
All pressure-relief device inlets shall under maximum filling conditions be situated in the vapour space of the closed cryogenic receptacle and the devices shall be so arranged as to ensure that the escaping vapour is discharged unrestrictedly.
Additionally, all closed cryogenic receptacles shall undergo the initial inspections
means the maximum effective gauge pressure permissible at the top of a loaded closed cryogenic receptacle in its operating position including the highest effective pressure during filling and discharge.
Executive summary: For safety reasons EIGA proposes to maintain the mandatory application of orientation arrows on closed cryogenic receptacles in RID/ADR rather than follow the 14th Revised edition of the UN Recommendations on the Transport of Dangerous Goods.
the pressure(including accumulation) inside the closed cryogenic receptacle does not exceed 120% of the MAWP.
Closed cryogenic receptacles shall be subject to periodic inspections
corrosion resistant plate welded on the outer jacket of a closed cryogenic receptacle.
MAWP means the maximum effective gauge pressure permissible at the top of a loaded closed cryogenic receptacle in its operating position including the highest effective pressure during filling and discharge.
Closed cryogenic receptacles shall be subjected to periodic inspections
Closed cryogenic receptacles intended for the transport of refrigerated liquefied gases having a boiling point below -182 °C at atmospheric pressure shall not include materials which may react with oxygen