This display only appears if activation of“stop service” was selected at program step 19 or.
triple filter systems the input is blocked after the start of regeneration for the time entered at program step 23.1.
Example: 4-stage alternate switching The number of stages is determined at program step 2.1, and the length of the individual regeneration phases at program step 4.1.
By using customized program step by step starting from the simplest things to the most difficult.
If program step 5.1 and 5.2 are programmed at“Y” the outputs“CV2” and“SV2” are controlled parallel to the outputs“CV1” and“SV1”.
If you change settings or insert the program step into an existing measuring program,
To remove a program step: select the state of the channel(On,
Where“pulse switching”,“external switching“ or“SIATA” control was selected at program step 1, the pulse lengths of the individual pulses must also be entered.
Alternating with the‘amount of water remaining' of the current through flow(see program step 10.1: pulse count) or: The flushing time remaining(see program step 19) or:“No Autom.
Stage-valve“SIATA“ The number of stages is determined at program step 2.1, the length of the triggering pulse at program step 3.1 and the length of the individual regeneration phases at program step 4.1.
the two additional relays with the functions selected at program step 14 may be switched on and off manually by pressing the relevant key for approx. 5 seconds.
Example: 4-stage pulse switching The number of stages is determined at program step 2.1, the length of the triggering pulse at program step 3.1 and the length of the individual regeneration phases at program step 4.1.
Switchover of service valve If phase‘0' was entered as switch on point at program step 16.1, it has to be decided whether the open service valve of the filter in service is to be shut immediately when the additional program is switched on(Y/N)
A 2 filter system in alternating service always switches over to the standby filter, and program step 6.5 cannot be selected.
The program steps can be combined
Individual program steps can be deleted.
Program steps can no longer be restored once they have been deleted.
Integrated programmer for 10 program steps.
Programming for day or group of days. 56 program steps On, Off, On, or Off.
If one or both of the program steps are missing, then the measuring program cannot be executed.