HKC-HAX Series current sensor with a galvanic isolation between primary and secondary circuit.
Sub-D9 plugs according to CiA 303-1, galvanic isolation(1 kV, 1 sec.).
Galvanic isolation of the group of 8 input channels from ground and module logic.
Galvanic isolation is a means of preventing current from flowing directly between two communicating circuits.
Only real physical galvanic isolation guarantees complete elimination of ground hum and annoying background noises in any live or studio situation.
The IO-Link blocks with galvanic isolation for safety applications are controlled by an upstream safe logic unit.
The solution in such cases is to provide galvanic isolation of the temperature measurement system, or alternatively, to look at other temperature measurement methods.
The surface-mount transformer provides galvanic isolation with the output powered from a push-pull rectifier circuit, reducing the output-voltage ripple.
Isolated current-sense inputs: 5V, 12V, 24V signaling voltages accepted, up to 50 kHz, individual galvanic isolation up to 500VAC RMS.
The transformer provides the galvanic isolation between input and output, up to 1500VRMS.
The transformer provides the galvanic isolation between input and output, up to 1875VAC.
The current and voltage transducers measure DC, AC and complex waveform signals and provide galvanic isolation.
For wired interfaces, galvanic isolation is critical to meet the patient safety requirements of IEC 60601-1.
PV(II) series with its strong overload capability, output galvanic isolation and low harmonic current distortion, is the ideal solution for industrial applications.
Conclusion Galvanic isolation is an important requirement for the measurement and control systems needed to implement smart grids that integrate large numbers of solar photovoltaic inverters.
Another concern is that high-voltage gate drivers do not have galvanic isolation; instead, they rely on the IC's junction isolation to separate the high-side drive voltage from the low-side drive voltage.
The operating principle is similar to the buck-boost converter, but an additional transformer is used to achieve galvanic isolation of the input and output.
Isolated current-sense inputs: 5V, 12V, 24V signaling voltages accepted, up to 50 kHz, individual galvanic isolation up to 250VDC and 170VAC RMS.
All digital inputs are carefully managed through our high-precision master clock generator and feature full electric and galvanic isolation to eliminate contamination and ensure signal integrity.