ensure that the shield of the cable is jointed to provide continuity of data cable shield.
It is not recommended to use the sheath of the sensor or a cable shield as the monitoring conductor.
A separate PE conductor is required if the conductivity of the cable shield is< 50% of the conductivity of the phase conductor.
The cable shield may only be earthed(grounded) at one place on the power supply unit.
A terminal in the connection head means that the cable shield can be grounded by the shortest route.
Easy to use tie-wrap solution to squeeze off the end of your cable shield.
use a separate ground cable if the conductivity of the motor cable shield is less than 50% of that of a phase conductor and the cable has no symmetrical ground conductors.
The single-point load cell is based on the 6-wire technology and its cable shield is connected to the measuring body,
connect black wire to AI-, and connect the cable shield to the metal cable shield screw.
type CG. EM glands for shielded cables feature an inner shielding ring that connects to the cable shield to provide electromagnetic compatibility protection.
uses a wide conductive tape to cover the full circumference of the cable shield providing excellent performance for EMI applications.
The cable shield must not be connected to the internal ground terminal in the device
if the conductivity of the input cable shield is< 50% of the conductivity of the phase conductor.
pin 3 connected to the cable shield(ground), such as the Shure C20HZ high-impedance cable. .
the stator frame, ground the encoder cable shield at the drive and the encoder end.
The connection of the motor cable shield can be done using a pigtail connected to a PE screw(see image below), or by using a metallic cable gland
Use a separate grounding cable if the conductivity of the cable shield is< 50% of the conductivity of the phase conductor and there is no symmetrically constructed
Applications cable shielding and flexible duct for ventilation.
Cable shielding(wrapped around the cable). .
Multiple cable shielding, for maximum protector against radio frequency interference.