For the gaseous components, this is the transport time of the measured component from the sampling probe to the detector(see Figure 3.1);
The sampling probe shall be positioned within the dilution tunnel so that the sample is taken from a homogeneous diluent/exhaust mixture.
With the unique patented sampling probe, EasySampler quenches the sample at the point of sampling
The particulate sampling unit shall consist of a sampling probe(PSP) located in the dilution tunnel,
The dimensions of the particle sampling probe should be sized not to interfere with the operation of the partial flow dilution system.
The particulate sampling unit shall consist of a dilution tunnel, a sampling probe, a filter unit,
The dimensions of the particle sampling probe should be sized not to interfere with the operation of the partial flow dilution system.
The particulate sampling probe shall be installed in close proximity to the gaseous emissions sampling probe, and the installation shall comply with the provisions of paragraph 2.3.5.
The particulate sampling probe shall be installed in close proximity to the gaseous emissions sampling probe, but sufficiently distant as to not cause interference.
With the fractional sampling system, raw exhaust gas is transferred from the exhaust pipe EP to the dilution tunnel DT through the sampling probe SP and the transfer line TL.
The sampling probe shall be inserted as far as possible,
Raw exhaust gas is transferred from the exhaust pipe EP to the dilution tunnel DT through the sampling probe SP and the transfer tube TT due to the negative pressure created by the venturi VN in DT.
Raw exhaust gas is transferred from the exhaust pipe EP to the dilution tunnel DT through the sampling probe SP and the transfer tube TT by a flow divider that contains a set of orifices or venturis.
The sampling probe shall be inserted into the exhaust pipe to a depth of at least 300 mm into the pipe connecting the exhaust with the sampling bag and as close as possible to the exhaust.
Raw exhaust gas is transferred from the exhaust pipe EP to the dilution tunnel DT through the sampling probe SP and the transfer tube TT due to the negative pressure created by the venturi VN in DT.
to ensure a constant flow of the gas samples taken in the course of the test from sampling probe S1; the flow of the gas samples shall be such that,
raw exhaust gas is transferred from the exhaust pipe EP to the dilution tunnel DT through the sampling probe SP and the transfer tube TT.
The sample for all components may be taken with one sampling probe or with two sampling probes located in close proximity and internally split to the different analyzers.
uniform exhaust flow at the sampling probe.
The sampling probe may be located closer to the injection point if complete mixing is verified by comparing the tracer gas concentration with the reference concentration when the tracer gas is injected upstream of the engine.