英語 での Representation type の使用例とその 日本語 への翻訳
{-}
-
Colloquial
-
Ecclesiastic
-
Computer
-
Programming
In both cases, the macros are placed using the"Overview" representation type.
A function can be used in the project in different representation types simultaneously, but each representation type may occur only once per function.
This setting then overwrites the representation type determined from the connection targets.
To make a contact to a pair cross-reference contact, after placement you must select the"pair cross-reference" representation type at the symbol.
If necessary, you can, however, specify a representation type deviating from it during placement.
Automatic assignment of pages In the Generate PLC schematic dialog you select the representation type to be generated.
The"Pair cross-reference" representation type must be set for the solenoid symbol in the fluid schematic.
For functions and macros to be placed in operational sequence sheets, the"Functional" representation type is available.
Select the desired entry from the drop-down list: Not defined: This setting automatically determines the representation type from the connection targets.
In the case of a mixed view(single-line symbols on multi-line pages) you must enter the representation type into the connection definition point yourself.
P024018: Connection of the representation type'Function overview(fluid power)' has no correspondence in the schematic Open topic with navigation This functionality is only available for certain module packages.
P024017: Function of the representation type'Function overview(fluid power)' has no correspondence in the schematic Open topic with navigation This functionality is only available for certain module packages.
When you draw cable definition lines on schematic pages in EPLAN, the representation type property of the cable is automatically set to match the page type. .
User interface/ operation Routing connections are connections of the"3D mounting layout" representation type that are routed in the layout space, or connections of the"Topology" representation type that are routed in the topology.
For example, a solenoid was inserted on a fluid power schematic page as the operating element of a valve and the automatically assigned Representation type"Pair cross-reference" was changed manually.
If the Symbolic address(automatic) value is the same for different representation types of a function, then the Symbolic address field in each representation type that contains a value receives the value from the import file.
Within the macro file, the section from the fluid schematic must therefore be saved with the"Multi-line Fluid" representation type and the section from the electrical engineering schematic must be saved with the"Multi-line" representation type.
Representation type here does not have anything to do with the page type, this may well be"Schematic single-line"; decisive is the representation type of the main function, it must be"multi-line.
Macros with the 3D data and the"3D mounting layout" representation type are stored in parts management on the Mounting data tab in the Graphical macro field.
We recommend that you store the macro file with the 3D data and the"3D mounting layout" representation type in parts management on the Mounting data tab in the Graphical macro field.